Fuel Pressure Pulsation Damper: Testing and Inspection

PROCEDURE

1. Check that battery voltage is above 12 volts.

2. Disconnect the negative (-) terminal cable from the battery.

CAUTION:  Work must be started after 90 seconds from the time the ignition switch is turned to the LOCK position and the negative (-) terminal
cable is disconnected from the battery.

3. Remove the union bolt and 2 gaskets. and disconnect the fuel inlet hose from the fuel filter outlet.

CAUTION:  Put a shop towel under the fuel filter and slowly loosen the union bolt.

4. Install the fuel inlet hose and pressure gauge to the fuel filter outlet with 3 new gaskets and the union bolt (SST 09268-45012).

Torque: 29 Nm (22 ft lb)

5. Wipe off any splattered gasoline.

6. Using jumper connect terminals +B and FP of the Data Link Connector (DLC) 1 (SST 09843-18020).

Fuel Pressure Pulsation Damper|Locations|Page 2919 > < Fuel Pressure Pulsation Damper|Locations|Page 2917