Compression Check: Specifications

COMPRESSION PRESSURE

Std .........................................................................................................................................................................................  178 psi (1,226 kPa) or more
Limit ......................................................................................................................................................................................................  142 psi (981 kPa)
Max. difference ...............................................................................................................................................................................  14 psi (98 kPa) or less