5.

Install Terminal to Connector

Insert terminal into the new connector (see illustrations).

a)

Verify the terminal is properly crimped.

b)

Insert the terminal with the terminal retainer in the temporary lock position.

c)

Insert the terminal until the locking clip locks firmly in place.