Camry Sedan 4-Door V6-3.0L (1MZ-FE) (1994)
INSTALLATION
1. Install the removed parts in reverse order of removal procedure.
HINT:
- The tightening torque for the bolt used to install the expantion valve on the evaporator is shown below.
Specified torque: 5.4 Nm (4.8 ft.lb)
- The tightening torque for the bolts used to install the liquid and suction tube is shown below.
Specified torque: 9.8 Nm (7 ft.lb)
2. Replenish compressor oil if evaporator has been replaced.
Add 40 cc (1.4 fl.oz)
Compressor oil: ND OIL 8 or equivalent
3. Evacuate air in refrigeration system and charge with refrigerant.
Specified amount: 850 +/- 50 g (29.98 +/- 1.76 oz)
4. Inspect for leakage of refrigerant. Using a gas leak tester, check for leakage of refrigerant.