Camry Sedan 4-Door V6-3.0L (1MZ-FE) (1994)
Variable Induction Control Valve: Testing and Inspection
INSPECTION
1. With 26.7 kPa (7.9 in Hg) of vacuum applied to the Actuator, check that the Actuator rod and the valve moves.
2. One minute after applying the vacuum in step 1, check that the actuator rod does not return. If the operation is not as specified, replace the intake
air control valve.