Using an ohmmeter, check that there is continuity between the terminals.

Resistance:
At 20 °C (68 °F)

25 - 30 Ohms

At 120 °C (248 °F)

33 - 42 Ohms

If there is no continuity, replace the VSV.

3. INSPECT VSV FOR GROUND

Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.

4. INSPECT VSV OPERATION

a. Check that air flows from ports A to B.