Camry Solara SE L4-2164cc 2.2L DOHC (5S-FE) MFI (2000)
b. Check the field coil for ground.
Using an ohmmeter, check that there is no continuity between the field coil end and field frame.
If there is continuity, repair or replace the field frame.
4. INSPECT BRUSHES
Using vernier calipers, measure the brush length.
Standard length: 15.5 mm (0.610 in.)
Minimum length: 10.0 mm (0.394 in.)
If the length is less than minimum, replace the brush holder and field frame.
5. INSPECT BRUSH SPRING
Check the brush spring load.
Take the pull scale reading the instant the brush spring separates from the brush.
Standard spring installed load:
17.6 - 23.5 N (1.79 - 2.41 kg, 4.0 - 5.3 lb)