Throttle Valve Solenoid: Description and Operation

CIRCUIT DESCRIPTION

The shift solenoid valve SLN controls the hydraulic pressure acting on the accumulator control valve when gears are shifted and performs smooth gear
shifting.
The ECM determines optimum operating pressure according to the signals from the throttle position sensor, vehicle speed sensor and direct clutch speed
sensor and controls the volume of current flow to the solenoid valve.
The amount of current to the solenoid is controlled by the (*) duty ratio of ECM output signals, causing a momentary change to the hydraulic pressure
acting on the clutches during gear shifting.
When the duty ratio is high, the hydraulic pressure acting on the clutches is low.

(*) Duty Ratio 
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then

Duty Ratio = A/A+B * 100(%)