Camry Solara SLEV6 V6-3.0L (1MZ-FE) (2000)
6. 1MZ-FE engine models:
REMOVE SUCTION HOSE
a. Remove the suction hose clamping bolt.
b. Disconnect the wire harness clamp.
c. Loosen the nut and bolts and remove the suction hose.
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
7. 1MZ-FE engine models:
DISCONNECT DISCHARGE HOSE
Remove the bolt and disconnect the hose.
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
8. 1 MZ-FE engine models:
REMOVE GENERATOR
a. Disconnect the generator connector.
b. Remove the nut, and disconnect the generator wire.
c. Disconnect the wire harness from the clip.
d. Remove the pivot bolt, plate washer, adjusting lock bolt and generator.
9. 5S-FE engine models:
DISCONNECT DISCHARGE AND SUCTION HOSES
Remove the 2 bolts and disconnect both hoses.
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.