toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

VSV For Canister Closed Valve <--> [Canister Purge Volume Control Valve]|Testing and Inspection|Page 2138 > < VSV For Canister Closed Valve <--> [Canister Purge Volume Control Valve]|Testing and Inspection
Page 2
background image

Using an ohmmeter, check that there is continuity between the terminals.

Resistance:
At 20 ° C (68 ° F)

25 - 30 Ohms

At 120 ° C (248 ° F)

33 - 42 Ohms

3. INSPECT VSV FOR GROUND

Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.

4. INSPECT VSV OPERATION

a. Check that air flows from ports A to B.

b. Apply battery positive voltage across the terminals.

VSV For Canister Closed Valve <--> [Canister Purge Volume Control Valve]|Testing and Inspection|Page 2138 > < VSV For Canister Closed Valve <--> [Canister Purge Volume Control Valve]|Testing and Inspection