toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Radiator Cooling Fan Motor Relay|Testing and Inspection|Page 43 > < Radiator Cooling Fan Motor Relay|Testing and Inspection
Page 2
background image

b. Inspect the No.2 cooling fan relay continuity.

1. Using an ohmmeter, check that there is continuity between terminals 1 and 2.

If there is no continuity, replace the relay.

2. Check that there is continuity between terminals 3 and 4.

If there is no continuity, replace the relay.

3. Check that there is no continuity between terminals 3 and 5.

If there is continuity, replace the relay.

c. Inspect the No.2 cooling fan relay operation.

1. Apply battery positive voltage across terminals 1 and 2.
2. Using an ohmmeter, check that there is no continuity between terminals 3 and 4.

If there is continuity, replace the relay.

d. Reinstall the No.2 cooling fan relay.

4. INSPECT NO.3 COOLING FAN RELAY

a. Remove the No.3 cooling fan relay. (Marking: FAN NO.3)

b. Inspect the No.3 cooling fan relay continuity.

1. Using an ohmmeter, check that there is continuity between terminals 1 and 2.

If there is no continuity, replace the relay.

2. Check that there is no continuity between terminals 3 and 5.

If there is continuity, replace the relay.

Radiator Cooling Fan Motor Relay|Testing and Inspection|Page 43 > < Radiator Cooling Fan Motor Relay|Testing and Inspection