a. Set the window lock switch to the unlock position.
b. Connect the positive (+) lead from the battery to terminal 9 and the negative (-) lead to terminal 1, and check that all the illuminations light up.

c. Set the window lock switch to the lock position, check that all the passenger's power window switch illuminations go out.

If operation is not as specified, replace the master switch.

Using an ammeter:
INSPECT ONE-TOUCH POWER WINDOW SYSTEM/CURRENT OF CIRCUIT

a. Disconnect the connector from the master switch.
b. Connect the positive (+) lead from the ammeter to terminal 3 on the wire harness side connector and the negative (-) lead to negative terminal of

the battery.

c. Connect the positive (+) lead from the battery to terminal 4 on the wire harness side connector.
d. As the window goes down, check that the current flow is approximately 7 A.

e. Check that the current increases up to approximately 14.5 A or more when the window stops going down.

HINT:  The circuit breaker opens some 4 - 40 seconds after the window stops going down, so that check must be done before the circuit breaker
operates.

If the operation is as specified, replace the master switch.