toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Service Port HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 5952
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

1. Recover refrigerant in refrigeration system.
2. Remove pressure switch.

a. Disconnect the connector.
b. Remove the pressure switch from the liquid tube.

NOTE: Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.

Service Port HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 5952