Camry Wagon V6-180.5 2959cc 3.0L DOHC (3VZ-FE) (1993)
Hose/Line HVAC: Technician Safety Information
1. Using a recovery machine, recover refrigerant in system before removing the parts.
NOTE: Do not release refrigerant to atmosphere.
2. Insert a plug immediately in the disconnected parts to prevent the entry of moisture and dust.
3. Do not remove plug from new parts until immediately before installation.
4. Do not use burner for bending or lengthening operations on tube.
If the tubes are heated with a burner, a layer of oxidation forms inside the tube, causing the same kind of trouble as an accumulation of dust.
5. Discharge gas in new compressor from charging valve before installing. IT If the gas in new compressor is not discharged first, compressor oil will
spray out with gas when the plug is removed.