Camry Wagon V6-180.5 2959cc 3.0L DOHC (3VZ-FE) (1993)
Air Flow Meter/Sensor: Specifications
BETWEEN TERMINALS
RESISTANCE
VS - E2
200 - 600 Ohms
(Measuring plate fully closed)
20 - 1200 Ohms
(Measuring plate fully open)
VC - E2
200 - 400 Ohms
THA-E2
At -4°F (-20°C)
10 - 20 kOhms
At 32°F (0°C)
4 - 7 kOhms
At 68°F (20°C)
2 - 3 kOhms
At 104°F (40°C)
0.9 - 1.3 kOhms
At 140°F (60°C)
0.4 - 0.7 kOhms