toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 275
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

1. Recover refrigerant in refrigeration system.
2. Remove pressure switch.

a. Disconnect the connector.
b. Remove the pressure switch from the liquid tube.

NOTE: Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.

INSTALLATION

1. Install pressure switch.

a. Install the pressure switch to the liquid tube.

Specified torque: 9.8 Nm (7 ft lb)

NOTE: Lock the switch mount on the tube with an open end wrench. being careful not to deform the tube, and install the switch.

b. Connect the connector.

2. Evacuate air in refrigeration system and charge with refrigerant.

Specified amount: 950 +/- 50 g (33.51 +/- 1.76 oz)

3. Inspect for leakage of refrigerant. Using a gas leak tester, check for leakage of refrigerant from the pressure switch mount.
4. Inspect A/C operation.

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 275