Camry Wagon V6-2507cc 2.5L DOHC (2VZ-FE) (1988)
Using an ohmmeter, measure the resistance between the terminal +B and HT.
Resistance (Cold): 5.1 - 6.3 ohms at 2O°C (68°F)
If the resistance is not as specified, replace the sensor.
Using an ohmmeter, measure the resistance between the terminal +B and HT.
Resistance (Cold): 5.1 - 6.3 ohms at 2O°C (68°F)
If the resistance is not as specified, replace the sensor.