OPERATION

The sensor works on the principal that when the heated platinum wire is positioned within the air intake, the air volume can be measured by
monitoring changes in hot wire temperature. The temperature change is measured by the thermistor. Circuit feedback maintains the platinum wire
at a set temperature by controlling current flow through the circuit. The current flow is measured by the Engine Control Module as output voltage.