2. Remove V-bank cover. Using a 5 mm hexagon wrench, remove the 2 cap nuts and V-bank cover. Disconnect the Vacuum Switching Valve VSV

connector.

3. Inspect VSV for open circuit.

Using an ohmmeter check that there is continuity between the terminals.