toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Main Oxygen Sensors|Page 1825 > < Electrical Specifications|Page 1822
Page 1
background image

Oxygen Sensor: Testing and Inspection
Main Oxygen Sensors

PROCEDURE

1. Disconnect negative (-) terminal cable from battery.

CAUTION:  Work must be started after 90 seconds from the time the ignition switch is turned to the LOCK position and the negative (-) terminal
cable is disconnected from the battery.

2. Inspect heater resistance of Main Heated Oxygen Sensors.

^

Disconnect the Oxygen Sensor connectors.

Main Oxygen Sensors|Page 1825 > < Electrical Specifications|Page 1822