toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Oil Pressure Switch (For Fuel Pump) > < Diagram Information and Instructions|Page 1940
Page 1
background image

Air Flow Meter/Sensor: Service and Repair

REMOVAL

1. Disconnect negative (-) terminal cable from battery.

CAUTION: Work must be started after 90 seconds from the time the ignition switch is turned to the LOCK position and the negative (-) terminal
cable is disconnected from the battery.

2. Remove air cleaner hose.

^

Disconnect the Positive Crankcase Ventilation (PCV) hose.

^

Loosen the 2 hose clamps. and remove the air cleaner hose.

3. Remove the Mass Air Flow (MAF) Meter.

^

Disconnect the MAF Meter connector.

^

Remove the 2 bolts and MAF Meter.

INSTALLATION

1. Install MAF Meter

^

Insert the MAF Meter end into the air cleaner case.

^

Secure the MAF Meter with the 2 bolts.

Torque:  6.9 Nm (61 in lb)

^

Connect the MAF Meter connector.

2. Install Air Cleaner Hose

^

Install the air cleaner hose with the 2 hose clamps.

^

Connect the PCV hose.

Oil Pressure Switch (For Fuel Pump) > < Diagram Information and Instructions|Page 1940