Camry XLE Sedan L4-2164cc 2.2L DOHC (5S-FE) MFI (1999)
lock-up solenoid and causing lock-up operation.
3. STOP LIGHT SW CIRCUIT
If the brake pedal is depressed (Stop light SW ON) when driving in lock-up condition, a signal is input to TERMINAL STP of the engine control
module, the engine control module operates and continuity to the lock-up solenoid is cut.
4. OVERDRIVE CIRCUIT
-
O/D main SW ON
When the O/D main SW is turned ON (O/D OFF indicator light turns OFF), a signal is input to TERMINAL OD2 of the engine control module
and engine control module operation causes gear shift when the conditions for overdrive are met.
-
O/D main SW OFF
When the O/D main SW is turned to OFF, the current through the O/D OFF indicator light flows through the O/D main SW to GROUND.
Causing the indicator light to light up. At the same time, a signal is input to TERMINAL OD2 of the engine control module and engine control
module operation prevents shift into overdrive.