toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 8136 > < Symptom Related Diagnostic Procedures|Page 8134
Page 3
background image

a. Connect the positive (+) lead from the battery to terminal 3.
b. Connect the positive (+) lead from the ammeter to terminal 2 and the negative (-) lead to battery negative (-) terminal, and check that the

current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.

c. Disconnect the leads from terminals.
d. Approximately 60 seconds later, connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 3, and check

that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.

Using an ammeter with a current-measuring probe:

a. Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 2.
b. Attach a current-measuring probe to either the positive (+) lead or the negative (-) lead, and check that the current changes from approximately

3.2 A to less than 0.5 A within 20 to 70 seconds.

c. Disconnect the leads from terminals.
d. Approximately 60 seconds later, reverse the polarity, and check that the door lock moves to the LOCK position. If operation is not as

specified, replace the door lock assembly.

8. INSPECT INTEGRATION RELAY OPERATION

Door Lock Signal:

HINT:  When the relay circuit is as specified, inspect the door lock signal.

Type B:

Symptom Related Diagnostic Procedures|Page 8136 > < Symptom Related Diagnostic Procedures|Page 8134