toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Electrical Specifications|Page 6317 > < Neutral Safety Switch|Specifications|Page 6312
Page 1
background image

Starter Motor: Electrical Specifications
A140E Transmission

A140E Transmission 

Tightening Torque

Transaxle to Starter

27 ft.lb 

   

  

  

 

Solenoid terminal

5.9 Nm 

    

 

  

  

 

Starter through bolts

5.9 Nm 

    

 

  

  

 

Starter motor to clutch assembly

5.9 Nm 

    

 

  

  

 

End cover

1.5 Nm 

    

 

  

  

 

Solenoid end cover

2.5 Nm 

    

 

  

  

 

Commutator

Standard diameter

30 mm 

   

  

  

 

Minimum diameter

29 mm 

    

  

 

  

  

 

Standard undercut depth

0.6 mm 

    

  

 

  

  

 

Minumum undercut depth

0.2 mm 

    

  

 

  

  

 

Maximum runout

0.05 mm 

    

  

 

  

  

 

Brushes

Standard length

15.5 mm 

   

  

  

 

Minimum length

10 mm 

    

  

  

 

  

  

 

Brush spring tension

1.2kW starter 

   

  

               

 

Standard installed load

13.7 to 19.6 N 

    

  

  

  

 

  

  

 

Minimum installed load

9.8 N 

    

  

  

  

 

  

  

 

1.4kW starter 

    

  

  

  

 

  

                 

 

Standard installed load

17.6 to 23.5 N 

    

  

  

  

 

  

  

 

Minimum installed load

11.8 N 

    

  

  

  

 

  

  

 

Solenoid contact plate

Maximum wear

0.9 mm 

   

  

  

 

No-load test

90 A 

@11.5 volts minimum

 

   

                      

  

 