REMOVE GENERATOR

4. 2ZZ-GE:

REMOVE NO. 1 VENTILATION PIPE
a. Remove the 2 nuts, bolt and gasket.

HINT:  At the time of installation, please refer to the following items. Use a new gasket.

b. Remove the hose clamp and disconnect No.1 ventilation pipe.

5. 1ZZ-FE:

REMOVE CAMSHAFT TIMING OIL CONTROL VALVE
a. Disconnect the oil control valve connector.
b. Remove the bolt and oil control valve.

Torque:  7.5 N.m (80 kgf.cm, 66 in.lbf)

c. Remove the O-ring from the oil control valve.

HINT:  At the time of installation, please refer to the following items. Use a new O-ring.

6. 2ZZ-GE:

REMOVE 2 CAMSHAFT TIMING OIL CONTROL VALVES
a. Disconnect the oil control valve connector.
b. Remove the 2 bolts and oil control valves.

Torque:  8.5 N.m (87 kgf.cm, 75 in.lbf)