Refueling Vapor Cut Valve: Testing and Inspection

INSPECT FUEL CUTOFF VALVE AND FILL CHECK VALVE

a. Disconnect the purge line hose and EVAP line hose from the charcoal canister.
b. Plug the cap to the air drain hose.
c. Pressurize 4 kPa (41 gf/sq.cm, 0.58 psi) to the purge port and check that there is ventilation through the EVAP line hose.

HINT:  In the condition that the fuel is full, as the float value of the fill check valve is closed and has no ventilation, it is necessary to check the fuel
amount (volume).

d. Check if there is anything stuck in the vent line hose and EVAP line hose.

If there is nothing stuck in them, replace the fuel cut off valve and fill check valve.

e. Reconnect the purge line hose and EVAP line hose to the charcoal canister.