Celica L4-1.8L (2ZZ-GE) (2005)
Canister Purge Solenoid: Testing and Inspection
VSV For Evaporative Emission (EVAP)
1. REMOVE VSV
a. Disconnect the 2 EVAP hoses from the VSV.
b. Disconnect the VSV connector.
c. Remove the bolt and VSV.
2. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the terminals.
Resistance: 27 - 33 Ohm at 20 °C (68 °F)
If there is no continuity, replace the VSV.
3. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.
4. INSPECT VSV OPERATION
a. Check that air flows with difficulty from port E to port F.