Celica L4-122 1998cc 2.0L DOHC Turbo (3S-GTE) (1990)
4. INSPECT COOLING FAN MOTOR
(a) Connect battery and ammeter to the fan motor connector.
(b) Check that the fan motor rotates smoothly, and check the reading on the ammeter.
Standard amperage: M/T 3.2 - 4.4 A