toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Evaporator Temperature Sensor / Switch|Locations|Page 136 > < Evaporator Temperature Sensor / Switch|Locations
Page 1
background image

Evaporator Temperature Sensor / Switch: Testing and Inspection

1. Disconnect negative cable from battery.
2. Remove glove box and under cover.
3. Check thermistor installed operation. Using an ohmmeter, measure the resistance at the connector.
4. Remove thermistor.

a. Disconnect the connector.
b. Remove the screw and thermistor from the cooling unit.

5. Check thermistor operation.

a. Place the thermistor in cold water. While varying the temperature of the water, measure the resistance at the connector and, at the same time,

measure the temperature of the water with a thermometer.

b. Compare the two readings on the chart.

If the intersection is not between the two lines, replace the thermistor.

Evaporator Temperature Sensor / Switch|Locations|Page 136 > < Evaporator Temperature Sensor / Switch|Locations