Celica GT L4-1.8L (1ZZ-FE) (2001)
3. Install a terminal bolt.
4. Install a O-ring.
5. Install a terminal insulator (outside).
6. Install a wave washer.
7. Install a terminal nut.
NOTE: Be careful to install the terminal insulator (inside) in the correct direction.
f.
Temporarily tighten the terminal nuts.
g. Tighten terminal nut.
1. Put a wooden block on the contact plate and press it down with a hand press.
Dimensions of wooden block:
20 x 37 x 40 mm (0.79 x 1.46 x 1.57 in.)
Press force:
981 N (100 kgf, 221 lbf)
NOTE:
Check the diameter of the hand press ram. Then calculate the gauge pressure of the press when 981 N (100 kgf, 221 lbf) of force is
applied.
Gauge Pressure
If the contact plate is not pressed down with the specified pressure, the contact plate may tilt due to coil deformation or the tightening of
the nut.