Refrigerant Pressure Sensor / Switch: Service and Repair

PRESSURE SWITCH REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

INSTALLATION HINT:  Evacuate air from refrigeration system.
See: Heating and Air Conditioning/Service and Repair/Discharging & Evacuating System

Charge system with refrigerant and inspect for leakage of refrigerant.
See: Heating and Air Conditioning/Service and Repair/Charging the System

Specified amount:

650 ± 50 g (22.92 ± 1.76 oz.)

2. REMOVE PRESSURE SWITCH

a. Disconnect the connector.
b. Remove the pressure switch from the liquid tube.

Torque: 10 N.m (100 kgf.cm, 7 ft.lbf) 

INSTALLATION HINT:  Lubricate a new O-rings with the compressor oil and install the switch.

HINT:  Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube. and remove the switch.

INSTALLATION

Installation is in the reverse order of removal.