toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Door Switch > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 455
Page 1
background image

Light Control Rheostat: Testing and Inspection

INSPECT LIGHT CONTROL RHEOSTAT

1. Connect the positive (+) lead from the battery to terminal 1 and negative lead (-) to terminal 3.
2. Connect the positive (+) lead from the voltmeter to terminal 2 and negative lead (-) to terminal 3.
3. Turn the rheostat knob and check that the voltage changes.

Door Switch > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 455