toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Bolt Inspection|Page 1289 > < Connecting Rod|Page 1286
Page 1
background image

Connecting Rod: Testing and Inspection
Bolt Inspection

1. Using vernier calipers, measure the minimum diameter of the compressed bolt at the measuring point. 

Standard diameter: 8.860 - 9.000 mm (0.3488 - 0.3543 inch) 
Minimum diameter: 8.60 mm (0.3386 inch) 
If the diameter is less than minimum, replace the connecting rod bolt.

Bolt Inspection|Page 1289 > < Connecting Rod|Page 1286