Corolla CE Sedan 4-Door L4-1587cc 1.6L DOHC MFI (1997)
Torque Converter: Testing and Inspection
TORQUE CONVERTER
Torque Converter Cleaning
-
If the transaxle is contaminated, the torque converter and transaxle cooler should be thoroughly flushed with ATF.
Torque Converter Inspection
1. INSPECT ONE-WAY CLUTCH
a. Install SST in the inner race of the one-way clutch. SST 09350-32014 (09351-32010)
b. Install SST so that it fits in the notch of the converter hub and outer race of the one-way clutch.
SST 09350-32014 (09351-32020)
c. With the torque converter clutch standing on its side, the clutch should lock when turned counterclockwise, and should rotate freely and
smoothly clockwise. If necessary, clean the converter and retest the clutch. Replace the converter if the clutch still fails the test.