Alarm Horn Relay: Diagnostic Aids

Connector Connection and Terminal Inspection

HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE

1.  CONNECTOR CONNECTION AND TERMINAL INSPECTION

For troubleshooting, diagnostic trouble code charts or problem symptom table are provided for each circuit with detailed inspection procedures.

When all the component parts, wire harnesses and connectors of each circuit except the ECU are found to be normal in troubleshooting, then it is
determined that the problem is in the ECU. Accordingly, if diagnosis is performed without the problem symptoms occurring, refer to Step 8 to replace
the ECU. So always confirm that the problem symptoms are occurring, or proceed with inspection while using the symptom simulation method.

The instructions "Check wire harness and connector" and "Check and replace ECU" which appear in the inspection procedure, are common and
applicable to all diagnostic trouble codes. Follow the procedure outlined below whenever these instructions appear.

OPEN CIRCUIT:

This could be due to a disconnected wire harness, faulty contact in the connector, and a connector terminal pulled out, etc.

HINT:  It is rarely the case that a wire is broken in the middle of it. Most cases occur at the connector. In particular, carefully check the connectors of
sensors and actuators.

Faulty contact could be due to rusting of the connector terminals, to foreign materials entering terminals or a deformation of connector terminals. Simply
disconnecting and reconnecting the connectors once changes the condition of the connection and may result in a return to normal operation. Therefore in
troubleshooting, if no abnormality is found in the wire harness and connector check, but the problem disappears after the check, then the cause is
considered to be in the wire harness or connectors.