toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Cooling Fan Relay|Page 1376 > < Cooling Fan Relay|Page 1374
Page 3
background image

c. Inspect the No. 3 cooling fan relay continuity. 

1) Using an ohmmeter, check that there is continuity between terminals 1 and 2.

If there is no continuity, replace the relay. 

2) Check that there is no continuity between terminals 3 and 5.

If there is continuity, replace the relay. 

d. Inspect the No. 3 cooling fan relay operation. 

1) Apply battery positive voltage across terminals 1 and 2.
2) Using an ohmmeter, check that there is continuity between terminals 3 and 5.

If there is no continuity, replace the relay. 

e. Reinstall the No. 3 cooling fan relay. 
f.

Reinstall the relay box cover. 

No. 2 & 3 Cooling Fan Relay

INSPECTION

1. REMOVE COOLING FAN RELAY NO.2 (Marking: AC FAN NO.2) FROM RELAY BLOCK NO.5

Cooling Fan Relay|Page 1376 > < Cooling Fan Relay|Page 1374