toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Condenser HVAC|Testing and Inspection|Page 5217 > < Condenser HVAC|Testing and Inspection
Page 1
background image

Condenser HVAC: Service and Repair

CONDENSER REMOVAL

1. Discharge Refrigerant From Refrigeration System.

INSTALLATION HINT:  Evacuate air from refrigeration system.

See: Service and Repair/Discharging & Evacuating System

Charge system with refrigerant and inspect for leakage of refrigerant.

See: Service and Repair/Charging the System

Specified amount: 700 ± 50 g (24.69 ± 1.76 oz.)

2. Remove These Parts:

a. Radiator Grille.
b. Hood Lock.
c. Center Brace.
d. Radiator reservoir tank and bracket.
e. Receiver and holder.
f.

Headlight RH.

3. Remove Condenser Fan.

a. Disconnect condenser fan harness.
b. Remove the 2 clips.
c. Pull out the condenser fan.

4. Remove Oxygen Sensor.

a. Disconnect oxygen sensor harness.
b. Remove the 2 nuts, 2 bolts and oxygen sensor.

Torque:

Bolts:  19.7 N.m (201 kgf.cm, 15 ft.lbf)
Nuts:  20 N.m (204 kgf.cm, 15 ft.lbf)

Condenser HVAC|Testing and Inspection|Page 5217 > < Condenser HVAC|Testing and Inspection