toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Distributor, Ignition > < Ignition Cable|Specifications
Page 1
background image

Ignition Cable: Testing and Inspection

Plug Wire Removal

Disconnect High-tension Cords From Spark Plugs

- Disconnect the high-tension cords at the rubber boot. 

NOTICE:Pulling on or bending the cords may damage the conductor inside.

Remove IIA (Distributor) Cap Without Disconnecting High-tension Cords

Checking Wire Resistance

Inspect High-tension Cord Resistance

- Using an ohmmeter, measure the resistance without disconnecting the IIA cap.

Maximum resistance: 25 k ohms per cord

- If the resistance is greater than maximum, check the terminals. 
- If necessary, replace the high-tension cord and/ or IIA cap.

Distributor, Ignition > < Ignition Cable|Specifications