EGR Valve: Testing and Inspection

EGR SYSTEM INSPECTION 

1. INSPECT AND CLEAN FILTER IN EGR VACUUM MODULATOR

-

Remove the cap and filter.

-

Check the filter for contamination or damage.

-

Using compressed air, clean the filter.

-

Reinstall the filter and cap.

HINT: Install the filter with the coarser surface facing the atmospheric side (outward).

2. INSTALL VACUUM GAUGE

-

Using a 3-way connector, connect a vacuum gauge to the hose between EGR valve and VSV.

3. INSPECT SEATING OF EGR VALVE

-

Start the engine and check that the engine starts and runs at idle.

4. CONNECT TERMINALS TE1 AND E1 OF DATA LINK CONNECTOR 1

-

Using SST, connect terminals TE1 and E1 of the data link connector 1. SST 09843-18020

5. INSPECT VSV OPERATION WITH COLD ENGINE

-

The engine coolant temperature should be below 47 °C (117 °F).

-

Check that the vacuum gauge indicates zero at 2,500 rpm.

6. INSPECT OPERATION OF VSV AND EGR VACUUM MODULATOR WITH HOT ENGINE

-

Warm up the engine to above 53 °C (127 °F).

-

Check that the vacuum gauge indicates low vacuum at 2,500 rpm.