toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Ignition Cable|Specifications|Page 2567 > < Ignition Cable|Specifications
Page 1
background image

Ignition Cable: Testing and Inspection

HIGH-TENSION CORDS INSPECTION 

1. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS

-

Disconnect the high-tension cords at the rubber boot.

-

Do not pull on the cords.

NOTICE: Pulling on or bending the cords may damage the conductor inside.

2. DISCONNECT HIGH-TENSION CORDS FROM DISTRIBUTOR CAP

-

Using a screwdriver, lift up the lock claw and disconnect the holder from the distributor cap.

-

Disconnect the high-tension cord at the grommet. Do not pull on the cords.

NOTICE: Pulling on or bending the cords may damage the conductor inside.

3. INSPECT HIGH-TENSION CORD RESISTANCE 

-

Using an ohmmeter, measure the resistance. 

maximum resistance: 25 kohm per cord 

-

If the resistance is greater than maximum, check the terminals.

-

If necessary, replace the high-tension cord.

Ignition Cable|Specifications|Page 2567 > < Ignition Cable|Specifications