Cressida L6-3.0L DOHC (7M-GE) (1989)
Cold Start Injector Time Switch: All Technical Service Bulletins
Fuel - Hard Starting/Long Cranking Time
REFERENCE
ENGINE
NUMBER
010
DATE
09-01-89
MODEL
MA7, MX8
TITLE 7M-GE, 7M-GTE HARD STARTING/LONG CRANKING TIME
A new cold start time switch is now available for improved startability:
Condition
Hard start/long crank time after dead soak when coolant temperature is above 22~C (72~F).
Application
1986-1989 Supra, 1989 Cressida w/ 7M-GE or 7M-GTE
Correction
Modified cold start time switch. Operating temp: Previous = 22~C (72~F) --> New = 45~C (113~F)
SERVICE INFORMATION:
Before replacing the cold start time switch, perform a thorough inspection to verify that all engine mechanical, fuel, and electrical/electronic systems are
operating within recommended specifications.
PART NUMBER INFORMATION