toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 5593 > < Diagram Information and Instructions|Page 5591
Page 1
background image

Control Assembly: Testing and Inspection

INTEGRATION CONTROL AND PANEL 

INSPECTION 

1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY

a. Check the blower switch resistance.

1. Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table.

If the result is not as specified, replace the integration control and panel assembly.

b. Inspect the illumination operation.

1. Connect the positive (+) lead from the battery to terminals 1 (IG+) and 2 (ILL+) and the negative (-) lead to terminal 20 (GND), then check

that the illuminations light up.

Diagram Information and Instructions|Page 5593 > < Diagram Information and Instructions|Page 5591