Highlander 2WD L4-2.4L (2AZ-FE) (2001)
5. While holding the air inlet port closed, apply vacuum (3.43 kPa, 25.7 mm.Hg, 1.01 in.Hg) to the EVAP port and check that air flows into the
purge port.
If operation is not as specified, replace the charcoal canister.
6. Remove the hose and cap from vent port.