toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Timing Components > < Variable Valve Timing Actuator Position Sensor|Locations|Page 1774
Page 2
background image

1. INSTALL VVT SENSOR (for Bank 1)

a. Apply a light coat of engine oil to the O-ring on the VVT sensor (Bank 1).
b. Install the VVT sensor (Bank 1) with the bolt.

Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)

c. Connect the VVT sensor (Bank 1) connector.

2. INSTALL VVT SENSOR (for Bank 2)

a. Apply a light coat of engine oil to the O-ring on the VVT sensor (Bank 2).
b. Install the VVT sensor (Bank 2) with the bolt.

Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)

c. Connect the VVT sensor (Bank 2) connector.
d. Install the heated oxygen sensor connector (Bank 2) to the wire harness bracket.

3. INSTALL AIR CLEANER CAP W/ INLET

Timing Components > < Variable Valve Timing Actuator Position Sensor|Locations|Page 1774