Yaw Rate Sensor: Testing and Inspection

CALIBRATION

1. DESCRIPTION

After replacing the VSC relevant components or performing "Front wheel alignment adjustment", clear and read the sensor calibration data.
Follow the chart to perform calibration.

2. CLEAR ZERO POINT CALIBRATION (WHEN USING INTELLIGENT TESTER):

a. Connect the intelligent tester to the DLC3.
b. Turn the ignition switch on.
c. Operate the intelligent tester to erase the codes (select "RESET MEMORY").

HINT:  Refer to the intelligent tester operator's manual for further details.

d. Using the intelligent tester, perform zero point calibration of the yaw rate and deceleration sensor.

3. PERFORM ZERO POINT CALIBRATION OF YAW RATE AND DECELERATION SENSOR (WHEN USING INTELLIGENT TESTER):