Evaporative Check Valve: Service and Repair

REPLACEMENT

1. REMOVE VENTILATION VALVE SUB-ASSY

a. Disconnect the ventilation hose from the ventilation valve.
b. Remove the ventilation valve.

2. INSTALL VENTILATION VALVE SUB-ASSY

a. Install the ventilation valve.

1. Apply adhesive to 2 or 3 threads.

Adhesive: Part No. 08833-00070, THREE BOND 1324 or equivalent

2. Install the ventilation valve.

Torque: 19 N.m (193 kgf.cm, 14 ft.lbf)

b

Connect the ventilation hose to the ventilation valve.