toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Components|Page 1634 > < Components|Page 1632
Page 1
background image

Air Cleaner Housing: Service and Repair
Installation

2GR-FE INTAKE: AIR CLEANER AND HOSE: INSTALLATION

INSTALLATION

1. INSTALL INTAKE AIR RESONATOR

(a) Tighten the bolt to install the intake air resonator.

2. INSTALL NO. 1 AIR CLEANER HOSE

(a) Align the tab on the air cleaner cap with the groove on the air cleaner hose and tighten the bolt.

HINT:
-

A = 30°

-

B = 11 to 14 mm (0.433 in. to 0.551 in.)

3. INSTALL NO. 3 INTAKE AIR CONTROL VALVE ASSEMBLY

(a) Engage the 2 claws and install the No. 3 intake air control valve assembly.

4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

(a) Install the air cleaner case with the 3 bolts.

Torque: 5.0 Nm (51 kgf-cm, 44 in-lbf)

(b) Connect the hose and connector.

5. INSTALL AIR CLEANER CAP SUB-ASSEMBLY

Components|Page 1634 > < Components|Page 1632