toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT:  At the time of installation, please refer to the following item.

Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount: 650 ± 50 g (22.93 ± 1.76 oz.)

2. REMOVE RADIATOR GRILL

3. REMOVE PRESSURE SWITCH FROM LIQUID TUBE

Disconnect the connector and remove the pressure switch.

Torque: 10 Nm (100 kg.cm, 7 ft.lb)

HINT:
-

Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.

-

At the time of installation, please refer to the following item.
Lubricate a new O-ring with compressor oil and install the switch.

INSTALLATION

Installation is in the reverse order of removal 

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection