2. REMOVE GENERATOR DRIVE BELT

Loosen the belt tension by turning the belt tensioner counterclockwise, and remove the drive belt.

HINT:  The pulley bolt for the belt tensioner has a left-hand thread.

3. REMOVE ENGINE UNDER COVER NO.1
4. REMOVE RADIATOR ASSEMBLY 
5. REMOVE PS VANE PUMP PULLEY

6. REMOVE GENERATOR

a. Disconnect the generator connector
b. Remove the rubber cap and nut, and disconnect the generator wire.
c. Disconnect the generator wire clamp from the cord clip on the generator.
d. Remove the bolt, nut and generator.

INSTALLATION

1. INSTALL GENERATOR

a. Install the generator with the bolt and nut.

Torque: 39 Nm (400 kg.cm, 29 ft.lb)

b. Connect the generator connector.
c. Connect the generator wire with the nut and rubber cap.
d. Install the generator wire clamp to the cord clip on the generator.

2. INSTALL PS VANE PUMP PULLEY 

Generator <--> [Alternator]|Removal and Installation|Page 3876 > < Generator <--> [Alternator]|Removal and Installation|Page 3874