e. Check that the current increases up to approximately 14.5 A or more when the window stops going down.

HINT:  The circuit breaker opens some 4 - 40 seconds after the window stops going down, so that check must be made before the circuit breaker
operates.

If operation is not as specified, replace the master switch.

INSPECT POWER WINDOW SWITCH CONTINUITY

If continuity is not as specified, replace the switch.

1. INSPECT POWER QUARTER WINDOW SWITCH CONTINUITY

Power Window Switch|Testing and Inspection|Page 6540 > < Power Window Switch|Testing and Inspection|Page 6538